# Z Axis

## What is the Z Limit Switch Holder?

This is the Z Limit Switch Holder.

![](/files/-LQ6B2fMsVGqWsnnhQNK)

## Warning

Exercise caution if you attempt to fit your head underneath the bed. The frame could potentially cause lacerations. &#x20;

* Use protective headgear (e.g. tear-resistant fabric).
* Enter slowly. Do not rush.&#x20;
* Make sure the bed is properly restrained.

## Tools

* T10 Screwdriver
* Flush Cutter (or any cutting pliers will do)

## Additional Hardware

* Nylon Zip tie (1x)

## How to Uninstall

### All Versions

Unscrew previous Z Limit Switch Housing.

![](/files/-LIrt04Sp_ZJtpQJSDeV)

Remove (Clip) Zip Tie.

![](/files/-LIrsyDC3kXzxCjJKXYo)

Remove Limit Switch from previous casing.

* Suggestion: Use a long screwdriver to push the end-stop out of its casing (e.g. Philips head, flat head).
* Video Demonstration: ??

Disconnect Z Limit Switch from Duet Board

![](/files/-LIs-pqM-W8oBc-Tr8y6)

* Refer to " \[ Duet Wiring Guide Name] " for additional help.

## How To Install

### Notes

A zip tie must secure the Z Limit Switch wire. If not, it runs the risk of entangling (and potentially breaking) with a moving bed.

### Version: 051162\_B1

Fit the Limit Switch Wire through the side slit on the Z Limit Switch Housing.

![](/files/-LIs2lqSYGHH6eFk8Zm7)

Firmly press/slide the Limit Switch into Z Limit Switch Housing.

* Make sure to press it in fully in, until a hard stop is reached.

![](/files/-LIs2oSLT1StUVcCcgsY)

Route Limit Switch Wire through side slot.

![](/files/-LIs2q7suCJN51ACoST8)

Screw down the Z Limit Switch Housing.

* Face the lever toward the rails.
* Remember to check for Limit Switching Wire.
  * It must route through the shorter side slot.
  * Do not let the wire compress between the Housing & the Sheet Metal.

![](/files/-LIs1MpTt9zNt0zZOXnA)

Connect Limit Switch Wire to the Duet Board.

![](/files/-LIs-pqM-W8oBc-Tr8y6)

* Refer to “ \[ Duet Wiring Guide Name ]” for additional help.

Install Zip Tie.

* Using the previous holes.

![](/files/-LIs2-sKXMuh72DIfIPO)

* Refer to “ \[ Zip Tie Hole Guide Name ] “ for additional help.

### Version: 051162\_B2

Fit the Limit Switch Wire through the bottom slit on the Z Limit Switch Housing.

![](/files/-LIs2sv5hOjONSQ000AE)

Firmly press/slide the Limit Switch into Z Limit Switch Housing.

* Make sure to press it in fully in, until a hard stop is reached.

![](/files/-LIs2oSLT1StUVcCcgsY)

Route Limit Switch Wire through side slot.

![](/files/-LIs2q7suCJN51ACoST8)

Screw down the Z Limit Switch Housing.

* Face the lever toward the rails.
* Remember to check for Limit Switching Wire.
  * It must route through the side slot.
  * Do not let the wire compress between the Housing & the Sheet Metal.

![](/files/-LIs3CeKrwl15BhdNukx)

Connect Limit Switch Wire to the Duet Board.

![](/files/-LIs-pqM-W8oBc-Tr8y6)

* Refer to “ \[ Duet Wiring Guide Name ]” for additional help.

Install Zip Tie.

* Using the previous holes.

![](/files/-LIs3R8rLjgw5uxeKT0G)

* Refer to “ \[ Zip Tie Hole Guide Name ] “ for additional help.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://promega.printm3d.com/repair-and-maintenance/install-uninstall/limit-switch-holder/z-axis.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.